safety-critical-embedded
by mojoatomic
rc sub controller
SKILL.md
name: safety-critical-embedded description: Safety-critical embedded system design patterns. Use when building dual-core safety monitors, failsafe systems, watchdog implementations, or any system where failure could cause harm. Covers isolation, fault detection, and emergency procedures.
Safety-Critical Embedded Systems
Design patterns for embedded systems where failure modes must be managed and safety cannot be compromised.
Core Principle: Defense in Depth
No single point of failure. Every safety mechanism has a backup.
┌─────────────────────────────────────────────────────────────┐
│ SAFETY LAYERS │
├─────────────────────────────────────────────────────────────┤
│ Layer 1: Software assertions (P10_ASSERT) │
│ Layer 2: Runtime fault detection (safety monitor) │
│ Layer 3: Hardware watchdog (independent timer) │
│ Layer 4: Physical failsafe (mechanical, electrical) │
└─────────────────────────────────────────────────────────────┘
Dual-Core Architecture
Isolate safety-critical code from complex logic.
┌─────────────────────────────────────────────────────────────┐
│ CORE 0 (Safety) │ CORE 1 (Application) │
│ ───────────────── │ ──────────────────── │
│ • Cannot be blocked │ • Can be complex │
│ • Minimal code │ • Runs control algorithms │
│ • Feeds watchdog │ • Reads sensors │
│ • Monitors faults │ • Updates actuators │
│ • Triggers emergency │ • State machines │
│ • 100 Hz fixed loop │ • 50 Hz or variable │
│ │ │
│ If Core 1 dies, Core 0 │ Core 1 checks │
│ still triggers failsafe │ is_emergency_active() │
└─────────────────────────────────────────────────────────────┘
↕ Shared State (volatile, atomic) ↕
Core 0 Requirements
- Maximum 200 lines total
- No blocking calls
- No dynamic memory
- No complex logic
- Fixed execution time
- Always feeds watchdog
// Core 0 main loop - MINIMAL
void core0_main(void) {
safety_init();
const uint32_t period_us = 10000; // 100 Hz
uint32_t next_us = time_us_32();
while (1) {
watchdog_update();
safety_monitor_run();
if (g_emergency_active) {
emergency_maintain();
}
// Fixed timing
next_us += period_us;
while (time_us_32() < next_us) {
tight_loop_contents();
}
}
}
Cross-Core Communication
Use volatile variables with atomic semantics:
// Shared state - declared volatile
static volatile uint32_t g_core1_heartbeat = 0;
static volatile bool g_emergency_active = false;
static volatile FaultFlags_t g_faults = {0};
// Core 1 increments heartbeat each loop
void core1_loop(void) {
g_core1_heartbeat++; // Atomic on ARM Cortex-M
// ... rest of loop
}
// Core 0 detects stall
void check_core1_health(void) {
static uint32_t last_seen = 0;
static uint32_t stall_count = 0;
if (g_core1_heartbeat == last_seen) {
stall_count++;
if (stall_count > STALL_THRESHOLD) {
trigger_emergency(FAULT_CORE1_STALL);
}
} else {
stall_count = 0;
}
last_seen = g_core1_heartbeat;
}
Fault Detection
Fault Categories
typedef union {
struct {
uint16_t signal_lost : 1; // No RC signal
uint16_t low_battery : 1; // Below threshold
uint16_t leak_detected : 1; // Water ingress
uint16_t over_temp : 1; // Thermal limit
uint16_t depth_exceeded : 1; // Beyond max depth
uint16_t pitch_exceeded : 1; // Beyond safe angle
uint16_t core1_stall : 1; // Application hung
uint16_t watchdog_warn : 1; // Near timeout
uint16_t sensor_fault : 1; // Invalid readings
uint16_t reserved : 7;
} bits;
uint16_t all;
} FaultFlags_t;
Detection Patterns
// Signal loss - timeout based
void check_signal(uint32_t now_ms) {
if ((now_ms - g_last_valid_signal_ms) > SIGNAL_TIMEOUT_MS) {
set_fault(FAULT_SIGNAL_LOST);
}
}
// Threshold - hysteresis to prevent flapping
void check_battery(void) {
uint16_t mv = adc_read_battery();
if (mv < BATT_CRITICAL_MV) {
set_fault(FAULT_LOW_BATTERY);
} else if (mv > BATT_RECOVERY_MV) {
clear_fault(FAULT_LOW_BATTERY); // Only if recoverable
}
}
// Rate of change - detect sudden anomalies
void check_depth_rate(int32_t depth_cm, float dt) {
static int32_t prev_depth = 0;
int32_t rate = (depth_cm - prev_depth) / dt;
if (abs(rate) > MAX_DESCENT_RATE_CM_S) {
set_fault(FAULT_DESCENT_RATE);
}
prev_depth = depth_cm;
}
Emergency Procedures
Atomic Emergency State
Once triggered, emergency cannot be cancelled except by power cycle:
static volatile bool g_emergency_active = false;
static volatile uint8_t g_emergency_reason = 0;
void trigger_emergency(uint8_t reason) {
// Atomic set - cannot be undone
g_emergency_active = true;
g_emergency_reason = reason;
// Immediate safe state
actuators_safe_state();
// Log for post-mortem
log_event(EVT_EMERGENCY, reason);
}
bool is_emergency_active(void) {
return g_emergency_active;
}
Safe State Definition
Define what "safe" means for each actuator:
void actuators_safe_state(void) {
// Motors: stop
motor_set_speed(MOTOR_PUMP, 0);
motor_set_speed(MOTOR_PROP, 0);
// Valves: open (vent pressure)
valve_open(VALVE_VENT);
// Servos: neutral or safe position
servo_set(SERVO_RUDDER, SERVO_NEUTRAL);
servo_set(SERVO_ELEVATOR, SERVO_FULL_UP);
// Outputs: disable high-power
gpio_put(PIN_ENABLE_POWER, 0);
}
Emergency Maintenance Loop
Continuously enforce safe state in case something tries to override:
void emergency_maintain(void) {
// Re-assert safe state every cycle
actuators_safe_state();
// Blink LED fast to indicate emergency
static uint32_t blink_timer = 0;
if (++blink_timer % 10 == 0) {
gpio_xor_mask(1 << PIN_LED);
}
// Sound alarm if equipped
buzzer_pattern(PATTERN_SOS);
}
Watchdog Implementation
Hardware Watchdog
Use the MCU's hardware watchdog, not a software timer:
void safety_init(void) {
// Enable hardware watchdog - 1 second timeout
watchdog_enable(1000, true);
}
void safety_monitor_run(void) {
// Only feed if no faults - deliberate reset on fault
if (g_faults.all == 0) {
watchdog_update();
}
// Check all conditions...
}
Watchdog Starvation
If Core 0 detects an unrecoverable fault, stop feeding the watchdog:
void check_critical_faults(void) {
uint16_t critical_mask = FAULT_LEAK | FAULT_CORE1_STALL | FAULT_SENSOR;
if (g_faults.all & critical_mask) {
// Stop feeding watchdog - force reset
// Log will survive if in persistent memory
log_event(EVT_WATCHDOG_STARVATION, g_faults.all);
while (1) {
// Wait for hardware reset
tight_loop_contents();
}
}
}
Startup Sequence
Power-On Self-Test
bool power_on_self_test(void) {
bool pass = true;
// Check each subsystem
pass &= test_memory_integrity();
pass &= test_watchdog_functional();
pass &= test_sensors_responding();
pass &= test_actuators_range();
pass &= test_communication_link();
if (!pass) {
// Do not proceed - stay in safe state
log_event(EVT_POST_FAILED, get_post_failures());
actuators_safe_state();
}
return pass;
}
Core Launch Handshake
Verify Core 1 actually started:
#define CORE1_READY_MAGIC 0xC0DE1001
// In main()
int main(void) {
core0_init();
multicore_launch_core1(core1_main);
// Wait for handshake with timeout
uint32_t timeout = 0;
while (!multicore_fifo_rvalid() && timeout < 1000) {
sleep_ms(1);
timeout++;
}
if (timeout >= 1000) {
trigger_emergency(FAULT_CORE1_LAUNCH);
}
uint32_t magic = multicore_fifo_pop_blocking();
if (magic != CORE1_READY_MAGIC) {
trigger_emergency(FAULT_CORE1_LAUNCH);
}
// Core 1 is running, start safety monitor
core0_main();
}
// In core1_main()
void core1_main(void) {
core1_init();
// Signal ready
multicore_fifo_push_blocking(CORE1_READY_MAGIC);
// Run application
application_loop();
}
Testing Safety Systems
Fault Injection
#ifdef TEST_MODE
void inject_fault(FaultType_t fault) {
switch (fault) {
case FAULT_SIGNAL_LOST:
g_last_valid_signal_ms = 0; // Force timeout
break;
case FAULT_LOW_BATTERY:
g_test_battery_mv = 5000; // Force low reading
break;
case FAULT_CORE1_STALL:
// Core 1 test: stop incrementing heartbeat
break;
}
}
#endif
Safety Monitor Tests
Every fault condition must have a test proving it triggers emergency:
void test_signal_loss_triggers_emergency(void) {
// Setup
g_emergency_active = false;
g_last_valid_signal_ms = time_ms() - SIGNAL_TIMEOUT_MS - 100;
// Act
safety_monitor_run();
// Assert
TEST_ASSERT(g_faults.bits.signal_lost == 1);
TEST_ASSERT(g_emergency_active == true);
}
Summary
Safety-critical systems require:
- Isolation - Safety code runs independently of application
- Simplicity - Safety code is minimal and verifiable
- Redundancy - Multiple layers detect the same faults
- Fail-safe - Default state is always safe
- Testability - Every fault path is tested
- Auditability - All events are logged for post-mortem
Never compromise safety for features. If in doubt, trigger emergency and surface.
Score